In sulphur recovery units (SRUs), efficient heat recovery and process reliability are critical. Vrcooler designs and manufactures shell and tube heat exchangers specifically for use in waste heat boilers of Claus sulphur recovery processes, ensuring high thermal efficiency, corrosion resistance, and long service life in harsh process environments.
Application Overview
In the Claus process, hydrogen sulfide (H₂S)-rich gas is burned in a thermal reactor to form sulphur dioxide (SO₂) and elemental sulphur vapors. The hot reaction gas—often exceeding 1,000°C—passes through a waste heat boiler (WHB), where heat is recovered to generate steam for plant use.
Within this WHB system, the shell and tube heat exchanger plays a vital role in transferring heat efficiently from the high-temperature process gas to the water/steam circuit, while protecting downstream equipment from thermal damage.

Technical Features
Design Type: Shell and Tube Heat Exchanger integrated in Waste Heat Boiler
Typical Duty: Waste heat recovery from process gas 1,000–350°C
Working Mediums:
Tube Side: Boiler feed water / steam
Shell Side: Claus process gas
Design Pressure: Up to 40 bar(g) (customizable)
Design Temperature: Up to 1,050°C (gas side)
Performance Advantages
High Thermal Efficiency
Optimized tube bundle and baffle design maximize heat recovery from the hot Claus gas stream, increasing steam generation without excessive pressure drop.
Enhanced Corrosion and Erosion Resistance
The sulphur recovery process exposes materials to SO₂, SO₃, and H₂S—Vrcoolertech uses sulphur-resistant alloys and protective coatings to ensure long equipment life.
Low Fouling Design
The smooth internal surfaces and optimized gas velocity reduce sulphur deposition and fouling, extending cleaning intervals.
Custom Engineering
Each exchanger is designed according to plant specifications—process gas flow, temperature, steam pressure, and allowable pressure drop—to achieve precise performance targets.
Easy Maintenance and Inspection
Removable tube bundles, manways, and inspection ports allow for convenient maintenance and mechanical cleaning.
Function in the Claus Sulphur Process
Thermal Stage: H₂S is combusted to form SO₂ and elemental sulphur vapors.
Heat Recovery Stage: The hot reaction gases enter the waste heat boiler, where the shell and tube exchanger recovers heat to produce steam.
Sulphur Condensation: After cooling, sulphur vapors condense and are separated, while the cooled gas moves to catalytic conversion stages.
Efficient heat recovery here directly improves plant energy utilization and reduces the overall carbon footprint.