Marine freshwater generators are the core equipment to ensure the daily water supply of crew and mechanical operation, but many shipowners and marine engineers often encounter the problem of low water production, even failure to produce water when the ship is fully loaded. Recently, we have summarized the fault handling experience of a 300,000-ton bulk carrier’s freshwater generator, hoping to provide practical reference for peers in the industry.
The freshwater generator is designed with a daily water production capacity of 30 tons, which requires strict parameter control: the heating medium flow rate is 60m³/h, the evaporator inlet temperature is 80℃, the outlet maximum temperature is 65℃, and the pressure difference is 0.3bar; the cooling medium flow rate is 59m³/h, the condenser inlet temperature is 32℃, the outlet maximum temperature is 45℃, and the pressure difference is 0.3bar; the vacuum jet pump flow rate is 52m³/h, the inlet pressure is 4.7bar, and the outlet pressure is 0.8bar; the chamber vacuum degree is 90%~95%, the evaporation temperature is 45~50℃, and the feed water flow rate is about 7.6m³/h. The seawater pump model of the freshwater generator is CNL 80-80/200, with a designed displacement of 59m³/h and a total discharge pressure of 5.4bar.
In actual operation, the bulk carrier only produced 7 tons of water per day when unloaded, which was 23 tons less than the designed capacity. When fully loaded, it could hardly produce water. To maintain a high vacuum degree in the evaporation chamber of the freshwater generator, the crew had to continuously close the cylinder liner water inlet heating valve of the freshwater generator to only 1/4 opening. Due to the small heat of the heating medium entering the evaporator of the freshwater generator, the opening of the feed water valve could only be smaller, otherwise, the excessive unevaporated seawater would flow to the bottom of the evaporation chamber, triggering the high brine level alarm.
After professional inspection, it was found that the root cause of the fault was the corrosion of the mixing nozzle of the two-stage vacuum jet pump of the freshwater generator. The first-stage nozzle of the vacuum jet pump is used to suck the steam after seawater evaporation and make the steam flow in the condenser, while the second-stage mixing nozzle is used to suck the excess high-concentration brine after distillation in the evaporation chamber. The corrosion of the mixing nozzle leads to the decline of vacuum suction capacity, which directly affects the evaporation efficiency of seawater and the water production capacity of the freshwater generator.
After the emergency supply of jet pump spare parts to the ship when it berthed at the port, the crew replaced the mixing nozzle. After replacement, the unloaded water production capacity of the ship reached 23 tons per day, the opening of the evaporator heating valve and feed water valve was 100%, and the evaporation temperature was adjusted to 48℃ by controlling the bypass valve of the main engine cylinder liner water, with the vacuum degree maintained at 94% (seawater temperature 29℃), fully meeting the water demand of the ship.
As a professional supplier of marine heat exchange equipment and freshwater generator accessories, we remind all shipowners and engineers that the vacuum jet pump is a key component affecting the operation of the freshwater generator. Regular inspection and maintenance of the nozzle and other parts can effectively avoid the fault of low water production. At the same time, we provide customized spare parts for various types of freshwater generators, including vacuum jet pump nozzles, freshwater generator evaporator tubes, and condenser bundles, to help ships solve operational problems efficiently and reduce downtime losses.