Shell and Tube Steam Heat Exchangers in the Pharmaceutical Industry
Material heating and reaction
Chemical reaction temperature: In the drug synthesis process, many chemical reactions need to be carried out at a specific temperature conditions, shell and tube steam heat exchanger can provide the required heat. Such as in the production of antibiotics, some condensation, cyclization reaction needs to be heated from room temperature to 50 ℃ -100 ℃ reaction materials, through the shell and tube steam heat exchanger will be the heat of the steam to the material in the reaction kettle, precise control of the temperature, so that the reaction is carried out smoothly, to improve the conversion rate of the reaction and the purity of the product.
Dissolving and mixing heating: in pharmaceutical production, often need to dissolve a variety of raw materials, excipients, etc. in a specific solvent, and uniform mixing. Shell and tube steam heat exchanger can preheat the solvent or heating of the mixture to speed up the dissolution rate, so that the material is mixed more evenly. For example, in the production of oral liquid system agent, the drug components dissolved in water, the use of heat exchangers to heat the water temperature to 30 ℃ -40 ℃, can significantly improve the dissolution efficiency, to ensure product quality stability.
Distillation and concentration
Solvent recovery: In the pharmaceutical process, a large number of organic solvents will be used, such as ethanol, methanol, etc., in order to reduce costs and reduce environmental pollution, the need for solvent recovery and reuse. Shell and tube steam heat exchanger for the distillation tower to provide heat, so that the solvent in the mixture evaporates, through condensation to achieve the separation of solvents and other substances. Ethanol recovery, for example, can contain ethanol mixture heated to the boiling point of ethanol near the ethanol evaporation and then cooled to collect, the recovery rate of up to 90% or more.
Concentration of medicinal liquid: For some traditional Chinese medicine extracts or the reaction liquid after the synthesis of western medicine, it needs to be concentrated. Shell and tube steam heat exchanger will steam heat transfer to the liquid, so that the liquid water and other solvents evaporate to achieve the purpose of concentration. For example, in the production of Chinese medicine injections, the Chinese medicine extract is heated and concentrated by shell and tube steam heat exchanger, so that the concentration of active ingredients is increased, which is convenient for the subsequent refining and preparation molding.
Drying
Drying of solid medicines: For tablets, granules and other solid medicines, drying is required in the production process to remove the water in order to ensure the stability and quality of the medicines. Shell and tube steam heat exchanger heats the air to form hot air to dry the solid drugs. For example, in the production of aspirin enteric-coated tablets, the tablets will be pressed into the drying equipment, the use of heat exchanger generated by the 60 ℃ -80 ℃ hot air for drying, so that the moisture content of the tablets to reduce to the prescribed standard range.
Drying of APIs: Drying of APIs has strict requirements on temperature and drying speed. Shell and tube steam heat exchanger can accurately control the drying temperature and time according to the characteristics of different APIs. For example, in the production of cephalosporin APIs, the use of shell and tube steam heat exchanger heated vacuum drying equipment, drying at a temperature of 40 ℃ -50 ℃, not only to ensure that the crystalline form of raw materials and purity, but also to improve drying efficiency and shorten the production cycle.
Sterilization and disinfection
Sterilization of pharmaceuticals: In the process of pharmaceutical production, many pharmaceuticals require final sterilization treatment to kill any microorganisms that may be present. Shell and tube steam heat exchanger generates high temperature steam for wet heat sterilization. For example, for some injectable drugs, moist heat sterilization at 121℃ for 15-20 minutes can effectively kill bacteria, spores and other microorganisms, ensuring the sterility and safety of drugs.
Sterilization of equipment and piping: Pharmaceutical equipment and piping need to be sterilized before and after use to prevent cross-contamination. Shell and tube steam heat exchanger provides high temperature steam to steam sterilize equipment and piping. For example, the piping system of infusion production line is regularly sterilized with high temperature steam at 130℃-150℃ for 30-60 minutes, which can completely remove microorganisms and impurities in the piping and ensure the hygiene of the pharmaceutical production environment.
Temperature regulation and control
Cooling system preheating: in the cooling system of pharmaceutical companies, sometimes need to preheat the cooling medium, in order to prevent damage to equipment or drug quality problems caused by low temperature in the cooling process. Shell and tube steam heat exchanger can be in the cooling system before the start of the cooling medium for proper heating, so that it reaches the appropriate temperature range.
Environmental temperature control: in the pharmaceutical production plant, need to maintain a certain temperature and humidity conditions to meet the pharmaceutical production process and quality requirements. Shell and tube steam heat exchanger can be used as part of the air conditioning system to provide heat for the workshop and regulate the temperature of the workshop. For example, in winter, the workshop temperature is maintained at 18℃-26℃ to ensure the stability of the pharmaceutical production environment.