What are the Design Points of Shell & Tube Biogas Heat Exchangers?
Design of process parameters
Determine the flow rate and flow velocity: According to the scale and actual demand of the biogas project, calculate the flow rate of biogas and heat exchanger medium accurately. Reasonable selection of flow rate, generally the flow rate of biogas in the tube is 0.5 - 3m/s, too high a flow rate will lead to excessive pressure loss, too low will affect the heat transfer effect.
Determine the temperature parameters: Define the inlet and outlet temperatures of the biogas as well as the inlet and outlet temperatures of the heat transfer medium. Biogas fermentation usually needs to maintain the temperature at about 35℃ - 55℃, the temperature parameters of the heat exchanger can be designed according to the specific process requirements to ensure that the biogas reaches the appropriate temperature conditions.
Calculation of heat transfer coefficient: According to the nature of the biogas and heat transfer medium, flow rate, heat exchanger structure and other factors, calculate the heat transfer coefficient by empirical formulas or refer to relevant manuals. For example, for heat transfer between biogas and water with forced convection, the heat transfer coefficient is generally between 10 - 100W/(m²・K).
Structural design
Selection of pipe diameter and length: The size of the pipe diameter influences the flow rate of the biogas and the heat transfer medium as well as the heat transfer area. Generally speaking, small pipe diameters are good for heat transfer coefficients, but increase the flow resistance; the opposite is true for large pipe diameters. Common tube diameters range from 20 - 50 mm. Tube length selection should take into account the overall layout of the heat exchanger and heat transfer effect, usually between 2 - 12m tube length.
Tube and shell arrangement: when the flow of biogas is small and the pressure is high, the biogas can be arranged in the tube, so as to facilitate the sealing and withstand high pressure; when the biogas flow is large, but the pressure is low, it can be considered to be arranged in the shell, in order to reduce the flow resistance. At the same time, according to the nature of the heat transfer medium and the flow rate to rationalize the arrangement of the tube range and shell range, in order to improve the heat transfer efficiency.
Folding plate design: set up in the shell process folding plate can increase the flow rate of the heat transfer medium and perturbation, improve the heat transfer effect. Folding plate spacing is generally 0.2 - 1 times the inner diameter of the shell, commonly used spacing of 0.3 - 0.6 times. The form of folding plate has bow-shaped, disk - circular and so on, bow-shaped folding plate is more widely used.
Material selection
Pipe selection: Since the biogas may contain hydrogen sulfide, carbon dioxide and other corrosive gases, the pipe should be made of corrosion-resistant materials. Stainless steel (such as 304, 316L stainless steel) is commonly used pipe materials, with good corrosion resistance and mechanical properties. For biogas with high sulfur content, special materials such as nickel-based alloy can also be considered.
Shell material: The shell is generally made of carbon steel to meet the requirements of structural strength. In order to prevent corrosion, anti-corrosion coating can be applied to the inner wall of the shell, such as epoxy resin coating and phenolic resin coating. When the shell needs to withstand high pressure, can choose high-strength carbon steel or low alloy steel.
Strength calculation and safety design
Pressure strength calculation: According to the working pressure of methane gas and heat exchanger medium, the strength calculation of heat exchanger shell, tube plate, header, flange and other components is carried out to ensure that they can withstand normal working pressure and possible pressure fluctuations.
Calculation of thermal stress: Due to the temperature difference between the biogas and the heat exchange medium, thermal stresses are generated in the components of the heat exchanger. Especially during start-up, stopping and change of working conditions, the thermal stress may cause damage to the equipment. Through thermal stress calculation, reasonable design of structure and support methods, such as the use of expansion joints and other components to compensate for thermal expansion, to reduce the impact of thermal stress.
Setting of safety accessories: Install safety valves, pressure gauges, thermometers and other safety accessories to monitor and control the operating parameters of the heat exchanger. The set pressure of the safety valve should be determined according to the design pressure of the equipment and relevant standards to ensure that the pressure can be relieved in a timely manner when the pressure exceeds the permissible value, to protect the safety of equipment and personnel.