Shell-and-Tube Heat Exchanger for Naphtha Heat Recovery
Time :Nov 24, 2026

The shell-and-tube heat exchanger is designed to preheat about 100 metric tons of naphtha per hour from 39.7°C to 298.9°C. The heat comes from a process stream that enters the tubes at 352.7°C and has a target outlet temperature of 99.8°C. As that stream cools, heat passes through the tube walls to the naphtha flowing around them. Recovering this heat reduces both the heating needed by the incoming naphtha and the cooling needed by the hot stream.

Operating conditionShell side · naphtha being heatedTube side · stream being cooled
Inlet temperature39.7°C352.7°C
Target outlet temperature298.9°C99.8°C
Inlet pressure (absolute)32.3 kgf/cm²22.6 kgf/cm²
Pressure drop0.50 kgf/cm²2.30 kgf/cm²
Average flow velocity2.17 m/s8.35 m/s

At the specified outlets, the heated naphtha is 199.1°C hotter than the cooled tube-side stream. Engineers call this a temperature cross. With countercurrent flow, the two outlets are at opposite ends. At the hot end, the 352.7°C tube-side inlet is 53.8°C warmer than the 298.9°C shell-side outlet. At the cold end, the 99.8°C tube-side outlet is still 60.1°C warmer than the incoming naphtha. The choice of shell and tube passes determines how closely the exchanger follows this countercurrent temperature profile. 


Both streams enter mostly as liquid, with gas making up 2.6% of the shell-side mass flow and 7.7% of the tube-side mass flow. Any vaporization as the naphtha warms, or condensation as the hot stream cools, contributes to the heat exchanged. A designer can account for both effects by calculating stream enthalpies from the actual mixture composition at the inlet and outlet conditions. Multiplying the shell-side enthalpy rise per kilogram by the naphtha mass flow gives the rate of heat recovery.

Shell-and-Tube Heat Exchanger for Naphtha Heat Recovery